71
Section D - Configuration, cont’d.
FIG. D34
FIG. D35
Two Rooftop Heat Pumps Plus One Gas Furnace
To configure two rooftop heat pumps plus one gas furnace,
ZONES need to be established. For explanation purposes,
the front unit will be ZONE 1 and the rear unit will be ZONE
2. Zones can be arranged per the customer’s wishes.
EACH unit must have AC power connected to it. Only one
unit requires 12V DC. Communications line must be be-
tween the Comfort Control Center and ONE unit.
A second communications line must be connected between
the two units control boxes.
Two (2) furnace thermostat wires must be routed to ONE
unit.
For explanation purposes the 12V DC, Comfort Control
Center telephone communications line and the two (2) fur-
nace thermostat wires are to ZONE 1 (front) unit.
ZONE 1 configuration should have all Dip switches to
OFF position. The cold (freeze) control is NOT used.
The P5 (blue) connector must stay open. The ambient
sensor must be plugged into the P3 (red) connector on
the AC power module.