Section B - Operation, cont’d.
FIG. B18
1
4
2
3
Wait at least two (2) minutes before restart-
ing the air conditioner after shutting off with
either the Heat/Off/Cooling Switch or the Tem-
perature Set Lever. This allows the refriger-
ant pressure in the air conditioner to equal-
ize and will allow the compressor to restart
easily.
Heating Operation
(If furnace is connected to thermostat)
Set Temperature Set Lever (1) to desired temperature level
(located at top of thermostat). Set the System Switch to
heat position (located at lower left side of thermostat(.
The furnace will now come on then heat is required and
cycle off when temperature level selected is reached.
Special Feature
When thermostat System Switch is in the OFF or HEAT
position and
Auto/On Switch
is in the ON position, the air
conditioner fan will run continuously to circulate the air in-
side the RV.
Heat Pump Operation -
See FIG. B18
1. Set the Temperature Set Lever (1) to desired tempera-
ture setting.
2. Set the System Switch (3) to heat pump position.
3. Move the FAN Auto/On Switch (2):
a. Auto Position: Unit fan runs whenever heat is re-
quired and stops whenever heating is not required.
b. ON Position: Unit fan runs continuously to circu-
late air in RV.
4. Select the desired fan speed by moving the fan speed
switch (4) to :
a. High speed: Selected for maximum air flow. The
discharge air will feel cool.
b. Low speed: Selected normally for heat pump op-
eration. The lower air flow allows it to feel warmer.
B2c. Analog Control System
In order to familiarize yourself with the operation of the
Analog Control System, the following diagrams along with
the accompanying text will explain all the functional char-
acteristics of the system.
FIG. B19
1. Temperature Set Lever
2. Fan Auto/On Switch
3. System Switch
4. Fan High/Low Switch
Analog Control Cooling Operation -
See FIG. B19
1. Place the Temperature Set Lever (1) to desired tem-
perature level.
2. Select desired fan speed by moving the Fan Speed
Switch (4) to:
a. High Speed: Selected when maximum cooling and
dehumidification are required.
b. Low Speed: Selected when RV reaches desired
comfort level and needs to be maintained. Normally
this speed is used for night time operation.
3. Move the FAN Auto/On Switch (2):
a. Auto Position: Unit fan runs whenever cooling is
required and stops whenever cooling is not re-
quired.
b. ON Position: Unit fan runs continuously to circu-
late air in RV.
4. Set the System Switch to cool position.
The unit compressor will now come ON and cycle OFF
when the temperature level selected is reached.
Furnace Operation
(If furnace is connected to relay box.) -
See FIG. B19
1. Set the Temperature Set Lever (1) to desired tem-
perature setting.
2. Set the System Switch (3) to furnace position. The fur-
nace will now come ON when heat is required and cycle
OFF when the temperature setting selected is reached.
25