66
Section D - Configuration, cont’d.
One Dual Basement Heat Pump Plus One Gas Furnace
To configure one dual basement heat pump plus one gas
furnace, the STAGE Dip switch on AC power module board
for Circuit 2 must be turned to ON. All other Dip switches
are OFF on both AC power module boards. Two (2) ambi-
ent sensors (one per AC power module board), are plugged
into the proper connector (red) on each AC power module
board. 115V AC (Circuit 1 and Circuit 2) are connected prop-
erly to CIR 1 and CIR 2 terminal blocks; 12V DC, two ther-
mostat wires from the furnace and telephone cable com-
munications line are properly connected to Circuit 1 AC
power module board in the electrical box.
Note:
If a remote sensor is used, it must be plugged into
the P4 (white) connector.
Improper connections can cause component
damage.
FIG. D22
FIG. D23
FIG. D24
115V AC
CIRCUIT 2
115V AC
CIRCUIT 1
Typical installation for one com-
fort zone with dual basement heat
pump and one furnace. Comfort
control may serve as a
roomtemperature sensor, or a re-
mote sensor may be used.