Section E - Symptom/Cause Chart, cont’d.
DUO-THERM BASEMENT HEAT PUMPS...
Continued
95
SYMPTOMS
CAUSE
REFER TO
PAGE
Fan operates; compressor will not
come on (does not “hum”).
Bimetal Control System
Operation
B2
24
Wiring
A3, C21
1, 58
Changeover Thermostat
C10
32
Cable Assembly
C19
52
Bimetal Thermostat
C18a
42
Relays
C16
35
Relay Board
C17a
38
Overload
C6
30
Compressor
C5
29
Analog Control System
Operation
B2d
25
Overload protector
C6
30
Compressor
C5
29
Fuse
C15
34
Breaker
A4
2
Wiring
A3, C21
1, 58
Analog Thermostat
C18d
50
Analog Control Box
C17b
39
Comfort Control Center System
Operation
B2d
26
Cable Assembly
C19
52
Wiring
A3, C21
1, 58
Overload
C6
30
Compressor
C5
29
AC Power Module Board
C17d
40
Comfort Control Center
C18d
52
3. Fan Operates; compressor tries to start,
cycles “OFF” and hums again, or blows
circuit breaker.
Bimetal Controls
AC Voltage
A1
1
PTCR or Start Relay
C4`
29
Start Capacitor
C3
28
Fan/Run Capacitor
C2
28
Overload
C6
30
Compressor
C5
29
Analog Controls
AC Voltage
A1
1
PTCR or Start Relay
C4`
29
Start Capacitor
C3
28
Fan/Run Capacitor
C2
28
Overload
C6
30
Compressor
C5
29
Manual
Compliments
of
Northwest
RV
Supply
Printed
From
http://www.nwrvsupply.com