Soft Serve Freezer Model GES-102
56
184559
15 VQM Error Codes
Error Code
Description/Action
Probable Cause
Remedy
MAIN COMM
The Main P.C. Board
has stopped receiving
messages from the User
Interface
Action: System shut
down completely.
Reset Method: Auto,
once condition is
rectified.
1. Faulty Wire
Connection
2.Programming Issue
3. Defective Board
1. Check Communication cable
between Main P.C. board and U.I.
board. (Contact H.C. Duke & Son
Factory Tech Support)
2. Ensure U.I. Program version
and Main P.C. Program Version are
compatible. (Contact H.C. Duke & Son
Factory Tech Support Software version
compatibility)
3. If the program versions are
compatible, and using the test cable
does not resolve the issue then the
main control board is not functioning
properly and needs to be replaced.
(Contact H.C. Duke & Son Factory
Tech Support)
NO COMM.
The U.I. Board is not
receiving messages
from the main board
Action: System shut
down completely.
Reset Method: Auto,
once condition is
rectified.
1. Faulty Wire
Connection
2.Programming Issue
3. Defective Board
1. Check Communication cable
between Main P.C. board and U.I.
board. (Contact H.C. Duke & Son
Factory Tech Support)
2. Ensure U.I. Program version
and Main P.C. Program Version are
compatible. (Contact H.C. Duke & Son
Factory Tech Support)
3. If the program versions are
compatible, and using the test cable
does not resolve the issue then the
U.I. board is not functioning properly
and needs to be replaced. (Contact
H.C. Duke & Son Factory Tech
Support)