Soft Serve Freezer Model GES-102
4
184559
CAUTION
To prevent accidental
electrical shock, a positive
earth ground is required.
2.4
Electrical Connections
Important!
A positive earth ground is required for
electronic VQM system
to operate correctly.
1. Double freezers with two compressors
require one power supply for each
side of the freezer. Each side of the
freezer operates independently.
2. Check the data plate for fuse
size, wire ampacity, and electrical
specifications. (See Figure 3-2)
3. Refer to the wiring diagram provided
for proper power connections.
4. Electrical connections are made in
the junction boxes located mid-level
behind the right side panel.
Important
Set switch next to the connection
box “UP” for 220-230v or “DOWN”
for 208-219V. Failure to set switch to
proper voltage will cause damage to
the electrical components and will void
all warranties.
5. Use a flexible connection when
permissible.
6. Beater Shaft Rotation Freezers are
designed for clockwise rotation when
viewed from front of freezer. 1ph
machines are prewired for proper
rotation. On 3phase machines, phase
wires to freezer should be connected
to produce proper beater rotation.
This is to be done by a freezer
technician.
WARNING
Warning:
When installing the machine,
insert an all pole disconnect, adequately
sized according to freezer nameplate
marking with electrical contact spacing
of 3mm minimum. This should be within
sight of the freezer.