43
ED50/ED100/ED250
09-2021
DL4617-003
dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Chapter 17
17.1 Connect accessory wiring, single door
17 Connect accessory wiring
17.1.1 Connect accessory wiring.
TIPS AND RECOMMENDATIONS
• Reference Chapter 8, Terminal
board connections, for
terminal board interfaces.
• Reference ED100/ED250
Sensor Installation and Wiring
Manual.
1. Terminate all accessory wiring at
ED50/ED100/ED250 low voltage
terminal board in header.
2. Secure all accessory wiring.
Fig. 17.1.1 Accessory wiring terminal board, ED100/ED250 operator on left example
17.2 Connect accessory wiring, double doors
17.2.1 Connect accessory wiring.
TIPS AND RECOMMENDATIONS
• Reference Chapter 8, Terminal
Board Connections, for
terminal board interfaces.
• Reference ED100/ED250
Sensor Installation and Wiring
Manual.
1. Terminate all accessory wiring for both
LH and RH doors at ED50/ED100/
ED250 low voltage terminal board
modules in header.
2. Secure all accessory wiring in header.
17.2.2 Panic breakout switch wiring.
Reference Para. 17.1.2.
17.2.3 Test system accessories.
Test functionality of all accessories.
17.1.2 Panic breakout switch wiring.
Reference OHC Installation Manual for
switch installation on inswing doors.
1. Breakout switch wires terminate at X6-4
and 4a on ED100/ED250 terminal board.
Remove jumper between 4 and 4a
(Fig. 17.1.2)
.
Fig. 17.2.1 Low voltage terminal board modules, double door
1
LH ED50/ED100/
ED250 controller
2
Low voltage
terminal board
module
3
RH ED50/ED100/
ED250 controller
1
2
2
3
1
Low voltage
terminal board
module
Fig. 17.1.2 Terminals 4 and 4a
4, 4a
Jumper
1