4 Technical data
Maximum wire size
Connector plug
screw size
16 AWG
1/16”
Door
status
X7
97,98,99
Sr
parameter
Door closed
Door open
Door closed, locked
Com, N.O., N.C.
contacts
4.1.5 Integrated functions.
Hold open time
Automatic opening
dd
parameter
0 to 30 s
Optional 0 - 180 s.
Hold open time
NIght / bank
dn
parameter
0 to 30 s
Hold open time
Manual opening
do
parameter
0 to 30 s
Door blocking
behavior
hd
parameter
Automatic, manual
door modes
Electric strike
delayed opening for
locking mechanism
Ud
parameter
0 to 4 s
Locking
device
feedback
X3
43, 3
Chapter 7
Motor lock
Wind load control,
maximum
Fo, Fc
parameters
33.7 lb f
150 N
Voltage independent
braking circuit
Chapter 12
Adjustable with
potentiometer
LED status indicators
Green, Red, Yellow
Chapter 6
24 Vdc power
Error codes
Service interval
Mode and Exit Only
switches
Auto, Close, Open
Exit only; Off, On
User interface
4 button keypad,
2 digit display
Slot for upgrade
cards
Chapter 20
Extension of
functional range.
Firmware update
Firmware update
TMP, temperature
management program
Overload
protection
IDC, initial drive control
Driving phase optimization
Cycle counter
CC
parameter
0 to 1,000,000
Power assist function
hA, hF, hS
parameters
Drive support for
manual opening of
door
Push & go function
PG
parameter
Auto opening of
door at 4° open
4.1 ED50/100/ED250 technical data
4.1.1 Required operating conditions.
Ambient temperature
5 to 122 °F
[-15 to 50⁰ C]
Suitable for dry
rooms only
Relative air humidity:
93% maximum, non-condensing
Power supply
115 Vac ±10%, 50/60 Hz
6.6 A maximum
Branch circuit
protection (provided
by others)
15 A maximum,
dedicated branch circuit
Protection class
NEMA 1 [IP20]
Power wiring:
black, white, bare
copper (ground)
12 AWG
maximum
Operating noise
Maximum 50 db(A)
4.1.2 General specifications.
Operator dimensions
(W x H x D)
27" x 2 3/4 x 5 1/8" [685 x 70 x 130 mm]
27" cover standard
Operator weight
21.8 lb [9.9 kg]
ED50: Power supply
for accessories
Separate power supply required.
ED100/ED250:
Power supply for
accessories
24 Vdc ± 5%, 1.5 A.
Maximum door
opening angle
95 to 110° depending on installation type
4.1.3 Inputs
Wire size
Connector plug
screw size
14 AWG
1/16”
Activation
inputs
X4*
Interior, exterior
N. O. contact
Safety
sensors
X5
Swing, approach sides.
Night-bank
(intercom
system)
X10
57,
57a
8-24 Vdc/Vac +5%
Night-bank
(key switch)
X1
35, 3
d2
parameter
Configure for N.O.
or N.C. contact
Deactivation
of drive
function
X6
4, 4a
d1
parameter
Configure for N.O.
or N.C. contact
4.1.4 Outputs
*
X4
:
terminal board numbers, reference Chapter 7,
Terminal board connections.