60
ED50/ED100/ED250
09-2021
DL4617-003
dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Appendix A
Parameter
Value
range
Units
Factory
setting
Description
Factory setting level
Parameter
SL
is used to determine what data will be reset during factory setting
process.
1
Reset Standard factory settings (SL=1 default)
1. Mode switch: CLOSE.
2. Door closed.
3. Press 4 button keypad down button
for greater than 8 s.
• All parameters reset to factory settings.
• Procedure completed when "8" on 2 digit displays blinks twice.
• Installed upgrade cards remain valid and do not require reinstallation.
4. Learning cycle required.
2 Reset Extended factory settings (SL=2)
1. Mode switch: CLOSE.
2. Door closed.
3. Set SL to 2.
4. Press 4 button keypad down button
for greater than 8 s.
• All parameters reset to factory settings.
• Installed upgrade cards deleted from operator memory.
• Parameter
SL
automatically reset to 1.
• Control unit and upgrade cards can be used independently (delivery status).
• Procedure completed when "8" on 2 digit displays blinks twice.
5. Learning cycle required..
32
1 - 2
1
Opening angle
• Door opening angle set during learning cycle is displayed.
• Opening angle can only be changed during learning cycle.
• Due to installation and parameter tolerances, display value may not match actual
door position.
33
0
- 110
°
Door closer mode
34
0 - 1
1
0
0
=Automatic mode. This mode is applicable whenever door is mainly opened
automatically and where motion detectors are installed.
• Mode is optimized for high frequency use.
• Full energy upgrade card provides for higher door opening and closing speeds.
• In case door is blocked during a closing cycle, operator reverses automatically.
• Driving phase is optimized to provide reliable closing cycles.
• Keep closed force (wind load control) parameter
FH
and Push & Go function
parameter
PG
are only available in automatic mode.
1
1
=Manual mode. This mode is applicable whenever door is mainly used manually
and only rarely automatically.
• In case door is blocked during a closing cycle, door will stop at its current
position.
• Driving phase optimized for manual opening cycles.
• Power assist function parameter
hf
is only available in manual mode.
Power assist activation angle
• Setting of door activation angle for Power assist function (
hF
).
• Higher settings of
hA
result in better spring force compensation for easier manual
opening.
• Power assist function is more sensitive the smaller the activation angle.
35
1 - 5
°
3
A.1.1 Driving parameters detail.