45
ED50/ED100/ED250
09-2021
DL4617-002
dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Chapter 19
ED100/ED250 Parameter
A156.10 standard
Parameter
Function
Factory setting
Adjustment range
Para. Requirement
So
Opening speed
automatic
mode
Swing door opening speed,
automatic mode.
25°/s
8°/s - 60°/s
10.2.1
Opening time of a swing door to 80 °, not less
than 1.5 s.
Sc
Closing speed
automatic
mode
Swing door closing speed,
automatic mode.
25°/s
8°/s - 60°/s
10.2.5
Closing time of a swing door to latch check.
Ref. Para. 19.1.2.
Fo
Static force
in opening
direction
Static force on door closing
edge in opening direction.
Parameter
setting *10
[60 N]
13.5 lb f
Parameter
setting *10
20 N - 130 N
4.5 lb f - 29.8 lb f
10.2.2
Shall not exceed 30 lb f [133 N] measured 1"
from lock edge of door.
Fc
Static force
in closing
direction
Static force on door closing
edge in closing direction.
Parameter
setting *10
[60 N]
13.5 lb f
Parameter
setting *10
20 N - 130 N
4.5 lb f - 29.8 lb f
10.2.7
Not to exceed 30 lb f [133 N] measured 1"
from lock edge of door at any point in closing
cycle.
bc
Backcheck
Checking or slowing down of
door speed before door being
fully opened.
10°
5° - 40°
10.2.3
Shall occur at no less than 10° of full open
position.
dd
Hold open
time
Open time for swing doors
using sensors or control mats
upon loss of detection.
5 s
0 s - 30 s
0 s - 180 s
F2 = 2.
10.2.4
Shall remain open a minimum of 1.5 seconds
after loss of detection.
Latch check
Checking or slowing down of
door speed before door being
fully closed.
Not adjustable
10.2.6
Shall occur for a swinging door at no less than
10° from closed position.
The door will not close through the final 10° in
less than 1.5 s.
hS
Reference
Appendix B for
parameter
detail
Support for manual mode in
door closed position.
10.2.8
Manual opening force in event of power failure.
Swing door shall be capable of being opened
manually with no greater than 30 lb f applied 1"
from edge of lock style to open.
hA
Adjustment, door activation
angle.
hF
Power assist function.
19.1 Power operated pedestrian doors (ANSI/BHMA 156.10)
The following table references portions of content from ANSI/BHMA A156.10. Refer to the standard, available
through ANSI or BHMA for additional information. Standard material reprinted with BHMA permission
.
19.1.1 Door measurements, power operated swing door.
"D" door width ,
minimum
(inches)
"W" door weight,
maximum
(pounds)
"T" closing time,
minimum, to latch
check (seconds)
36 or less
100
2.0
36
140
2.3
42
110
2.3
42
150
2.7
48
120
2.8
48
160
3.2
19.1.2 A156.10, 10.2.5 swing door closing time to latch check.
19.1.3 Other door weights and widths.
Closing time T = (D
W
)/188
D = Width of door in inches.
W = Weight of door in pounds.
T = Closing time to latch check in seconds.
19 ANSI/BHMA standards
"D" door width,
minimum
(inches)
"W" door
weight,
maximum
(pounds)
"T" closing
time, minimum
to latch check
(seconds)
48
160
3.2