16
ED50/ED100/ED250
09-2021
DL4617-003
dormakaba ED50/ED100/ED250 OHC Header
Setup and Troubleshooting Instructions
Chapter 9
9 ED50/ED100/ED250 door signage
Signage and warnings are specified in
ANSI /BHMA A156.10, American National Standard for
Power Operated Pedestrian Doors, paragraph 11.
9.1.2 Door, one way traffic, Fig. 9.1.1.
1. Arrow and AUTOMATIC DOOR, one side of decal.
• Shall be visible from approach side of a swinging door,
mounted on door at a height of 50" ± 12" from floor to
centerline of sign.
2. DO NOT ENTER and AUTOMATIC DOOR, one side of
decal (or separate decal for solid doors - DD0739-020).
• Shall be visible from non-approach side of door that
swings towards pedestrians attempting to travel in
wrong direction.
9.1.3 Door, two way traffic, Fig. 9.1.2.
1. Arrow and AUTOMATIC DOOR, one side of decal.
• Shall be visible from approach side of a swinging door,
mounted on door at a height of 50" ± 12" from floor to
centerline of sign.
2. CAUTION AUTOMATIC DOOR, one side of decal.
• Swinging doors serving both egress and ingress shall
have a "CAUTION AUTOMATIC DOOR" sign visible
from swing side of door.
• Sign shall be mounted on door at a height of 50 ± 12"
from floor to centerline of sign.
9.1.1 Overview
Fig. 9.1.1 One decal, approach side, non-approach side
9.1 Full energy operator
Fig. 9.1.2 One decal, two way traffic
Fig. 9.1.3 ACTIVATE SWITCH TO OPERATE decal
DD0739-010
DD0756-010
DD0758-010
AUTOMATIC
DOOR
DD0758-010
ACTIVATE SWITC
H
TO OPERATE
DD0758-010
AUTOMATIC
DOOR
DD0739-010
AUTOMATIC
DOOR
DO NOT
ENTER
CAUTION
DOOR
AUTOMATIC
DD0756-010
dormakaba
9.2 Low energy operator
9.2.1 Overview
Signage and warnings are specified in
ANSI /BHMA A156.19, American National Standard for
Power Assist and Low Energy Power Operated Doors.
9.2.2 All low energy doors.
1. AUTOMATIC CAUTION DOOR decal.
• All low energy doors shall be marked with signage
visible from both side of door with the words
"AUTOMATIC CAUTION DOOR".
• Signs shall be mounted 50" ± 12" from floor to
centerline of sign.
9.2.3 Knowing act switch used to initiate door operation.
1. ACTIVATE SWITCH TO OPERATE decal.
• When a knowing act device is used to initiate operation
of door operator, door shall be provided with sign on
each side of door where switch is operated with
message "ACTIVATE SWITCH TO OPERATE".
9.2.4 Push/Pull used to initiate door operation.
1. PUSH TO OPERATE, PULL TO OPERATE decals.
• When push/pull is used to initiate operation of door
operator, doors shall be provided with the message
"PUSH TO OPERATE" on push side of door and
"PULL TO OPERATE" on pull side of door.
9.1.4 Knowing act door.
1. ACTIVATE SWITCH TO OPERATE decal.
• Knowing act doors shall have signage stating
"ACTIVATE SWITCH TO OPERATE" on side of door
having knowing act switch or other knowing act device.
Fig. 9.2.1 AUTOMATIC CAUTION DOOR decal
Fig. 9.2.2 ACTIVATE SWITCH TO OPERATE decal
Fig. 9.2.3 PUSH TO OPERATE, PULL TO OPERATE decals
DD0758-010
DD0762-010
DD0762-020
CAUTION
DOOR
AUTOMATIC
DD0586-010
DD0586-010
1
Activate Switch to
Operate DD0758-010
DD0758-010
ACTIVATE SWITC
H
TO OPERATE
DD0758-010
1
2
Push to Operate
DD0762-010
3
Pull to Operate
DD0762-020
DD0762-010
PUSH
TO OPERATE
2
DD0762-020
PULL
TO OPERATE
3