background image

(P/N) 760.128 Rev G 12/13 • © copyright 2004-2013 

 

Kaba Mas LLC

 

Page 1 of 2

MANAGER INSTRUCTIONS

BASIC SERIES

3802 Firmware Dual-Handed Swing Bolt Lock or Dead Bolt

SUPER MASTER RESET (SMR)*
•  8 Digit code – default code 5-5-5-5-5-5-5-5 [consistent with other LA GARD locks]
•  If the default code is not changed before Manager changes his or her code then the SMR option will be lost, unless hard reset of the lock  
  is performed.
•  Once set the SMR cannot be changed, unless hard reset.

FACTORY RESET PROCEDURE 
Remove Battery. 
•  Hold down key “0” for 10 seconds to discharge all internal capacitors.  
•  Connect Reset Box (p/n 6066) to alarm box connector. Put the battery back in place, factory reset is completed. 
Disconnect Reset Box. 
•  Lock configuration is: only manager code exists, set to 1-2-3-4-5-6. Audit file not cleared.  
•  Lock is operational with manager code only; other users are deleted.

LOCK USERS
Manager
• Open Lock
• Change Combination
• Enable/Disable User
• Delete User
Users
• Open Lock
• Change Combination

STANDARD LOCK FEATURES
Wrong Try Penalty
•  Entry of four (4) consecutive invalid combinations initiates a five (5) minute delay penalty. Lock responses during the penalty period are  
  as follows:
  -  The LED will flash every ten (10) seconds. If any key is pressed, there is no response.
•  Once the penalty period has ended, two (2) consecutive invalid combinations will initiate another five (5) minute penalty period.
Low Battery Warning
•  Repeated audio/visual signals (LED flashes/beeps) during Lock opening indicate the battery is low and should be replaced immediately.
•  If the battery level becomes too low to safely operate the Lock, pressing any key will initiate the low battery warning. The battery must be  
  replaced before the Lock will operate.

LOCK OPERATING CONVENTIONS
•  If a mistake is made while entering keystrokes, wait thirty (30) seconds and repeat operation.
•  To access lock commands, enter combination and hold down the last digit until Lock double signals and the LED stays on.

LOCK RESPONSES
Standard Operations
•  Manager Menu – LED on  during operation
•  Double signal - two (2) LED flashes and two (2) beeps indicate entry is valid or accepted.
•  Triple signal - three (3) LED flashes and three (3) beeps indicate invalid or not accepted.
•  Lock must be opened within 4 seconds once a valid combination has been entered.
•  To open a container with a Swing Bolt Lock, turn the container handle to the open position and open the door.
•  To open a container with a Dead Bolt Lock, turn the keypad or dial to retract the bolt and open the door.
•  When closing a container, verify that it has been secured.

Dual-handed

Swing Bolt Lock

Dead Bolt Lock

3000 Entry

(Swing Bolt Only)

3750 Entry

KEYPADS:

LOCKS:

3715 Entry

(Swing Bolt Only)

3190 Privat

II

 

(Optional)

3710 Entry

(Swing Bolt Only)

3035 Entry