INT-SZK
Code lock
Firmware version 2.02
int-szk_en 08/20
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-
298 Gdańsk
• POLAND
tel. +48 58 320 94 00
www.satel.eu
Страница 1: ...INT SZK Code lock Firmware version 2 02 int szk_en 08 20 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...
Страница 2: ...rights under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the change...
Страница 3: ...ng 4 3 1 Description of parameters and options 4 4 Using 7 4 1 LED indicators 7 4 2 Sound signaling 7 4 2 1 Beeps generated when operating 7 4 2 2 Signaling events 7 4 3 Code 8 4 4 Available functions...
Страница 4: ...trol of 24 MONO switch and 25 BI switch type outputs The ability to change access code by the user LEDs indicating the lock and door status 12 keys with backlighting Built in sounder Tamper protection...
Страница 5: ...ig 2 Connecting the actuator to the code lock 9 If the code lock is to supervise the door status connect the detector supervising the door status to the IN and COM terminals If the code lock is not to...
Страница 6: ...n square brackets at the description of a parameter or option is the name presented on the display of the LCD keypad Name individual name of the device up to 16 characters Partition partition to which...
Страница 7: ...horized opening of the door when the partition is armed will trigger an alarm The option is available if the Authorization control option is enabled Max door open time Max door open the maximum period...
Страница 8: ...tr if this option is enabled the Mono output operating type of users can use the code lock to control outputs Partition blocking Part blocking if this option is enabled using the code by a user of the...
Страница 9: ...be unlocked in the event of fire alarm in the object to which the code lock belongs Fire alarm on any fire the door will be unlocked in the event of fire alarm in the alarm system 4 Using 4 1 LED indi...
Страница 10: ...orary block the partition 4 4 2 Triggering the alarm from keypad The installer can permit triggering alarms from the keypad To trigger an alarm do the following fire alarm press and hold down for abou...
Страница 11: ...SATEL INT SZK 9 Operating temperature range 10 C 55 C Maximum humidity 93 3 Dimensions 144 x 80 x 27 mm Weight 160 g...