INT-SZK
SATEL
Switch (ON position)
1
2
3
4
5
Number
1
2
4
8
16
Table 1.
Fig. 3. Examples of code lock address setting.
2.2 Description of terminals
NO
- relay output
IN
- door status input (NC)
COM
- common ground
+12V
- power input
DTA
- data (expander communication bus)
CLK
- clock (expander communication bus)
3. Configuring
The code lock settings you can configure using:
•
DLOADX program:
“Structure” window
“Hardware” tab
“Expansion modules”
branch
[code lock name]
,
•
LCD keypad:
“Service mode”
“Structure”
“Hardware”
“Expanders”
“Settings”
[code lock name]
.
3.1 Description of parameters and options
Names of parameters and options from the DLOADX program are used in this manual.
Shown in square brackets at the description of a parameter or option is the name presented
on the display of the LCD keypad.
Name
– individual name of the device (up to 16 characters).
Partition
– partition to which the code lock belongs (alarms will be triggered in this partition).
Lock features
[Lock function] – mode of operation of the relay output after the access is
granted:
Fixed ON time
[ON time] – the relay output will be turned on for the “Relay ON time”.
Fixed ON time – OFF if door open
[ON, open
off] – the relay output will be turned on
until the door is opened (door status input is disconnected from common ground),
however not longer than for the “Relay ON time”.
Fixed ON time – OFF if door closed
[ON, close
off] – the relay output will be turned on
until the door is closed (door status input is reconnected to common ground), however
not longer than for the “Relay ON time”.