6
INT-SZK
SATEL
Confirmation
– method of providing feedback to the user after using the code lock:
No
– no feedback.
Sound
– the code lock will use sounds to give feedback to the user.
Backlight
– the code lock will use key backlight to give feedback to the user.
Users
[Master users / Users] – the administrators and users which are permitted to use the
code lock.
FIRE alarm
– if this option is enabled, pressing and holding
for 3 seconds will trigger
the fire alarm.
AUX. alarm
[Medical alarm] – if this option is enabled, pressing and holding
for 3
seconds will trigger the medical alarm.
PANIC
alarm
– if this option is enabled, pressing and holding
for 3 seconds will trigger
the panic alarm.
silent
[Silent panic] – if this option is enabled, the panic alarm triggered from the keypad will
be a silent one, i.e. the code lock will not indicate it, there will be no audible signal, but the
alarm will be reported to the monitoring station. The silent panic alarm is useful when the
control panel is sending events to the monitoring station, but unauthorized persons should
not be aware of the alarm being triggered. This option is available, if the “PANIC alarm”
option is enabled.
Alarm 3 incorrect codes
[3 wrong codes] – if this option is enabled, entering a wrong code
three times will trigger an alarm.
Control “BI”
output
[BI outs ctrl.] – if this option is enabled, the ““Bi” output operating” type
of users can use the code lock to control outputs.
Control “MONO” output
[MONO outs ctr.] – if this option is enabled, the ““Mono” output
operating” type of users can use the code lock to control outputs.
Partition blocking
[Part.blocking] – if this option is enabled, using the code by a user of the
“Blocking partition” or “Guard” type will block the armed partition (violating a zone
belonging to the partition will trigger no alarm). The duration of blocking is to be defined for
the partition or the user (the user of “Blocking partition” type).
Guard round control
[Guard control] – if this option is enabled, using the code by a user of
the “Guard” type will be registered as the guard round.
Changing access code
[Changing code] – if this option is enabled, the user can change
own code from the code lock.
Acc. code sign. (hardware)
[Code entered] – if this option is enabled, the code lock will
confirm with a single beep that the code has been entered. The signaling is useful when
there is a delay between entering the code and the sounds emitted after verification of the
code by the control panel.
CHIME
[Chime zones] – if this option is enabled, the code lock will audibly signal violation of
zones with “Chime in module” option enabled, belonging to the same partition as code
lock.
No auto-reset after 3 tamp.
[No autorst.3t.] – if this option is enabled, the feature reducing
the number of tamper alarms from the module to three is disabled (the feature prevents
multiple logging of the same events and applies to successive uncleared alarms).
Backlight
– keys backlight operation mode:
No
– always off.
Auto
– on for about 40 seconds after pressing any key. Additionally, it can be turned on if
a specific event occurs (see the “Auto-backlight”
parameter).
Permanent
– always on.