ENiQ® Wall Readers & Terminals
_____________________________________________________________________________________
64
the signalling during programming.
The changeover contact is then actuated. The lower LED lights up green for the set
contact exposure time and you will hear an acoustic signal. Signalling takes place at
every unit connected.
ENiQ AccessManager®
Terminal
ENiQ
®
Passive
Reader
C:
The (intelligent) locking medium is authorised, is taking part in the extension of
authorisation period and extension has not worked.
If an error has occurred during programming of the extension of authorisation period
or if programming is cancelled, both LEDs flash briefly and the acoustic signal is
repeated three times.
In this case the changeover contact is not actuated and the locking medium is
rejected, as though it were an unauthorised locking medium. The upper LED then
flashes red briefly again twice. The upper red LED goes off on the other unit
connected.
ENiQ AccessManager®
Terminal
ENiQ
®
Passive
Reader
Upper LED
Tag is authorised at the ENiQ AccessManager® ITT (conventional
and intelligent):
A:
The (conventional or intelligent) locking medium is authorised and is not taking part
in data update.
The changeover contact is actuated. The lower LED lights up green for the set
contact exposure time and you will hear an acoustic signal.
DOM ACM ITT Mifare