ENiQ® Wall Readers & Terminals
_____________________________________________________________________________________
65
B:
The (intelligent) locking medium is authorised, is taking part in the data update and
programming of the data has worked.
The updated data are programmed first. During
programming the upper LED lights up orange.
The changeover contact is then actuated. The lower LED lights up green for the set
contact exposure time and you will hear an acoustic signal.
DOM ACM ITT Mifare
C:
The (intelligent) locking medium is authorised, is taking part in the data update but
data updating has not worked.
If an error has occurred during programming of the data or if programming is
cancelled, both LEDs flash briefly and the acoustic signal is repeated three times.
In this case the changeover contact is not actuated and the locking medium is
rejected, as though it were an unauthorised locking medium. The upper LED then
flashes red briefly again twice.
DOM ACM ITT Mifare
Upper LED