ENiQ® Wall Readers & Terminals
_____________________________________________________________________________________
63
transponders are still recognised and the changeover contact is actuated
(e.g. door is opened). Extensions of validity at the ENiQ AccessManager®
Terminal and ITT are still carried out. Changes in authorisation at the ENiQ
AccessManager® ITT on the other hand are
not
carried out.
The changeover contact is actuated. The lower LED lights up green during the
contact exposure time. Signalling takes place at every unit connected.
The lower LED lights up green in accordance with the contact exposure time and
you hear an acoustic signal. After the contact exposure time the green LED goes
off and the red LED is lit again permanently.
ENiQ AccessManager®
ENiQ
®
Passive Reader,
external reader of the ENiQ
®
Module Reader
Tag is authorised at the ENiQ AccessManager® Terminal
(conventional and intelligent):
A:
The (conventional or intelligent) locking medium is authorised and is not taking part
in extension of the authorisation period.
The changeover contact is actuated. The lower LED lights up green for the set
contact exposure time and you will hear an acoustic signal. Signalling takes place at
every unit connected.
ENiQ AccessManager®
Terminal
Mifare
ENiQ
®
Passive Reader
B:
The (intelligent) locking medium is authorised, is taking part in the extension of
authorisation period and programming of the extension has worked. Programming
of the extension of the authorisation period takes place first. There is no change in