62
Maintenance instructions • DINO 160XT II • 180XT II • 210XT II
7.1. SCHEDULE FOR INSPECTIONS REQUIRED BY THE AUTHORITIES
Inspections must be performed in accordance with local, state or federal regulations,
legislation, directives, standards.
The manufacturer recommends following inspections, as
required by local authorities in platforms country of origin.
A pre-use inspection must be done before taking the platform to use for the first time and
before first start-up after major repairs and alterations.
A thorough inspection and a test loading of the lift must be carried out at least once every
twelve (12) months.
The platform should undergo a major inspection within ten (10) years after having
been originally put into service. A major inspection includes non-destructive testing and
inspection while dis-assembled.
A special inspection should be done if the platform has been exposed to exceptional
circumstances which may have affected the structural integrity of critical components.
The inspections should be carried out on regular basis throughout the service life of the lift.
If the lift is used under extreme conditions, intervals between the inspections shall be
reduced.
The overall operating condition of the lift as well as the condition of the safety-related control
devices shall be established in the regular inspections. Particular attention shall be paid to
changes which affect the operational safety.
During inspections the notifications given in previous inspections, practical experience
from use and information on performed repairs should be taken into account and can be
implemented for better safety.
Major and special inspections shall be carried out by a competent person or competent
body, who is familiar with the operation and structure of the lift. The competent person sould
periodically update their knowledge and be able to demonstrate their competency if so
required.
A report should be made of the inspections and the reports should be kept with the unit
stored in the space reserved for it.
The report should include
- information about the inspection
- data of repair welds (date, what was repaired and repaired by whom)
When the lift is ready for operation after annual inspection, the date of inspection shall be
marked on the inspection plate affixed to the lift.
DANGER
WARNING
CAUTION
NOTICE
Check the regulations for the inspections and the competence of the inspector with
the local authorities.
Содержание DINO XT II 160
Страница 2: ......
Страница 6: ...6 Ekspluat cijas instrukcijas DINO 160XT II 180XT II 210XT II BLANK...
Страница 10: ...10 Operating instructions DINO 160XTB II 180XTB II 210XTB II 2 1 DIMENSION DRAWINGS 2 1 1 160 XTB II...
Страница 11: ...11 2 1 2 180 XTB II...
Страница 12: ...12 Operating instructions DINO 160XTB II 180XTB II 210XTB II 2 1 3 210 XTB II...
Страница 29: ...29 BLANK...
Страница 37: ...37 NOTES...
Страница 58: ...58 Operating instructions DINO 160XTB II 180XTB II 210XTB II NOTES...
Страница 59: ...59 NOTES...
Страница 63: ...63 7 2 LUBRICATION PLAN 6 9 7 11 7 8 1 5 5 3 2 12 3 4 10 13 14...
Страница 69: ...69 BLANK...
Страница 70: ...70 Operating instructions DINO 130T II BLANK...
Страница 72: ...72 Operating instructions DINO 130T II NOTES...
Страница 73: ...73 NOTES...