33
Battery gauge
(14)
1. As the current is switched on using the key switch, the operating hours
of the motor are displayed on the gauge for 5 seconds.
2. During normal operation, the state of charge of the batteries is
displayed in per cents.
3. If the motor controller observes malfunction, an error code is displayed.
The LED signal lights in the gauge indicate the current mode of the display
Left LED (green)
Middle LED (yellow)
Right LED (red)
ON - operating hours are
displayed
ON - state of charge of the batteries is
displayed in %
Flashes - state of charge below 10%
Flashes - error code
CODE
xx
DESCRIPTION
REMEDY
11
Internal current measurement error in the
controller.
Switch off the current and retry
12
Error in the internal safety circuit for the
controller.
Switch off the current and retry
13
Malfunction or short circuit of motor
connections
Check the power cables and wiring of the
motor.
14
Locking/malfunction in the directional
switch circuit
Check fuses, control circuit for the controller
and wiring.
21
Motor revolutions have been adjusted too
high
Check joystick and wiring of the control circuit.
22
Emergency reverse - not in operation
Controller incorrectly programmed
23
Locking/malfunction in the revolution
control circuit
Check fuses, control circuit for the controller
and wiring.
24
Motor revolutions adjusted to too low value Check joystick and wiring of the control circuit.
31
Excess current or short circuit in the main
contactor spool
Check the main contactor, replace as required
32
Tip of main contactor shorted out
Check the main contactor, replace as required
33
Field coil of the engine broken - not in use Controller incorrectly programmed
34
Control circuit for the main contactor spool
broken
Check whether the connector for the main
contactor is loose
41
Emergency stop circuit has been
disconnected or connected wrongly
Check the emergency descent pushbuttons
42
Excess voltage > 30VDC
Check operation of the battery charger
43
Temperature too high > 85 °C or too low <
-25 °C
Check ambient temperature
44
Locking/malfunction in the selector switch
circuit
Check fuses, control circuit for the controller
and wiring.
Capacity of the batteries is affected by the operating temperature.
100 % is reached at the temperature of 30 °C, at 0 °C the capacity is 80 % of normal, at -20
°C the capacity is 50 % of normal
DANGER
WARNING
CAUTION
NOTICE
When the charger is connected to mains, the display immediately shows 100 % even if the
batteries are not fully charged. You can check the state of charge of the batteries before
charging.
Always keep the charger connected for a sufficiently long time irrespective of the readout
on the display! The recharger is equipped with overcharge protection.
Содержание DINO XT II 160
Страница 2: ......
Страница 6: ...6 Ekspluat cijas instrukcijas DINO 160XT II 180XT II 210XT II BLANK...
Страница 10: ...10 Operating instructions DINO 160XTB II 180XTB II 210XTB II 2 1 DIMENSION DRAWINGS 2 1 1 160 XTB II...
Страница 11: ...11 2 1 2 180 XTB II...
Страница 12: ...12 Operating instructions DINO 160XTB II 180XTB II 210XTB II 2 1 3 210 XTB II...
Страница 29: ...29 BLANK...
Страница 37: ...37 NOTES...
Страница 58: ...58 Operating instructions DINO 160XTB II 180XTB II 210XTB II NOTES...
Страница 59: ...59 NOTES...
Страница 63: ...63 7 2 LUBRICATION PLAN 6 9 7 11 7 8 1 5 5 3 2 12 3 4 10 13 14...
Страница 69: ...69 BLANK...
Страница 70: ...70 Operating instructions DINO 130T II BLANK...
Страница 72: ...72 Operating instructions DINO 130T II NOTES...
Страница 73: ...73 NOTES...