DINO 105TL
22
10 MEASURES TO BE TAKEN IN THE CASE OF EMERGENCY/IF THE LIFT IS
AT RISK OF LOSING ITS STABILITY
Reduced stability can be caused by a fault in the lift, the wind or other
lateral force, collapse of the standing base or negligence in providing
sufficient support. In most cases one sign of reduced stability is the
inclination of the lift.
WHEN AT RISK OF LOSING THE STABILITY
1. If there is time, try to find out the reason for the reduced stability and the direction of its
effect. Warn other people on the worksite using the alarm signal.
2. If possible, reduce the load from the platform in a safe manner.
3. Reduce the outreach to the side by retracting the telescope. Avoid abrupt movements.
4. Turn the boom away from the danger zone, i.e. to a position where the stability of the lift
is normal.
5. Lower the boom.
If the stability has been lost as a result of a fault in the lift, repair such a fault immediately.
Do not use the lift until the fault has been repaired and the condition of the lift has
been verified.
IN CASE OF OVERLOADING
1. If there is time, try to find out the reason for the reduced stability and the direction of its
effect. Warn other people on the worksite using the alarm signal.
2. If possible, reduce the load from the platform in a safe manner.
3. Reduce the outreach to the side by retracting the telescope.
IN CASE THE POWER SUPPLY IS INTERRUPTED (electric motor)
1. Lower the boom using the emergency descent system (see point “Emergency descent
system”)
2. Establish the reason why the energy supply was interrupted.
IN CASE OF MALFUNCTION, WHEN EVEN THE EMERGENCY DESCENT SYSTEM IS
NOT OPERATIONAL
1. If the emergency descent system does not operate, try to warn other personnel present
on the site or call for help so that the power supply required for normal operation can be
resumed or the lift can be made operational by some other means so that the person on the
platform can be lowered safely down.
Содержание DINO 105TL
Страница 2: ...DINO 105TL 2 ...
Страница 3: ...DINO 105TL 3 ORIGINAL OPERATING INSTRUCTIONS Valid from serial number 10196 ...
Страница 6: ...DINO 105TL 6 HYDRAULIC DIAGRAM 10189 81 23 1 NOTES 82 ...
Страница 8: ...DINO 105TL 8 2 REACH DIAGRAM ...
Страница 9: ...DINO 105TL 9 3 DIMENSION DRAWING ...
Страница 35: ...DINO 105TL 35 o that the driving device is disconnected from the wheel ...
Страница 38: ...DINO 105TL 38 18 3 LUBRICATION PLAN 1 2 3 4 5 5 6 7 8 10 9 11 12 ...
Страница 41: ...DINO 105TL 41 ...
Страница 53: ...DINO 105TL 53 19 1 1 SAMPLE OF INSPECTION PROTOCOL FOR THE ACCESS PLATFORM ...
Страница 54: ...DINO 105TL 54 ...
Страница 69: ...DINO 105TL 69 21 1 NOTES ...
Страница 73: ...DINO 105TL 73 23 ELECTRIC DIAGRAM 105TL 10196 ...
Страница 74: ...DINO 105TL 74 ...
Страница 75: ...DINO 105TL 75 ...
Страница 76: ...DINO 105TL 76 ...
Страница 77: ...DINO 105TL 77 ...
Страница 78: ...DINO 105TL 78 ...
Страница 79: ...DINO 105TL 79 ...
Страница 80: ...DINO 105TL 80 ...
Страница 81: ...DINO 105TL 81 HYDRAULIC DIAGRAM 10189 ...
Страница 82: ...DINO 105TL 82 23 1 NOTES ...