Single-Ended I/O Modules
5–8 UltraSCSI RAID Enclosure
Table 5–2 UltraSCSI Bus Expansion Rules
1. The I/O module numbers (1–6) match the enclosure SCSI bus
numbers and the array controller port numbers.
CXO5819A
6
4
2
5
3
1
2. Always connect the cables between the I/O modules in the same
location on the same bus. That is, connect I/O module 1 on the
master enclosure to I/O module 1 on an expansion enclosure.
3. The
first cable on any I/O module always connects to the left
connector.
4. The
second cable on any I/O module always connects to the right
connector.
Cabling an UltraSCSI Subsystem
____________________ Caution ____________________
Not all array controllers support an UltraSCSI RAID subsystem
with more than one enclosure. Read the array controller
documentation to ensure the controller supports expanded
configurations.
________________________________________________
____________________ Caution ____________________
The DIGITAL UltraSCSI controller does not support connecting
or disconnecting a SCSI bus when both data and power are
present on the connector, a "hot swap." You can only connect
or disconnect SCSI bus cables using the cold swap method.
To replace a cable, (1) Shut down the array controller, and
(2) Turn off the enclosure power before removing an I/O
module.
____________________________________________________
Содержание StorageWorks UltraSCSI DS-BA370 Series
Страница 18: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...
Страница 54: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...
Страница 84: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...
Страница 120: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...
Страница 186: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...