Power Verification and Addressing (PVA)
4–6 UltraSCSI RAID Enclosure
Setting the Enclosure Address
Use the procedure in Table 4–2 to identify the enclosure as either a master
or an expansion enclosure. This switch also establishes the SCSI bus address
(device ID) for the disk drives (SBBs) in the enclosure. The following
restrictions apply to establishing the enclosure address:
1. The master enclosure address is always 0.
2. There is only one master enclosure in any subsystem.
3. No two enclosures can have the same address.
See Table 4–3 for the DIGITAL-supported enclosure addresses.
____________________ Caution ____________________
DIGITAL does not support any combination of enclosure
address settings that assign the same SCSI bus device address to
more than one device on a SCSI bus
To preclude SCSI bus addressing conflicts, DIGITAL only
supports enclosure address settings 0, 2, and 3.
________________________________________________
Table 4–2 Setting the Enclosure Configuration
DECREASE
SWITCH
INCREASE
SWITCH
0
CXO-4851A-MC
To decrease the configuration number:
Press the upper switch to step the address
down one address at a time (decrement).
To increase the configuration number:
Press the lower switch to step the address
up one address at a time (increment).
____________________ Caution ____________________
To implement an address setting change you must turn the
enclosure O
FF
and then turn it O
N
.
________________________________________________
Содержание StorageWorks UltraSCSI DS-BA370 Series
Страница 18: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...
Страница 54: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...
Страница 84: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...
Страница 120: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...
Страница 186: ...SES Template Word 7 Blank Page Fix by Peter LaQuerre...