Operating the UltraSCSI Enclosure
UltraSCSI RAID Enclosure 2–17
Table 2–7 Enclosure Status LED Displays
When the LED display is
Data
Center
Cabinet
Dept.
Server
Cabinet
The enclosure status is…
The enclosure is operating normally. There
are no detected errors.
There are one or more failed components.
1. Observe the EMU front panel to see if
there is an overtemperature condition, a
blower problem, or a power problem.
Replace the defective blower or power
components.
2. Observe individual SBBs for error
condition.
3. Check the array controller optional
system maintenance terminal for error
messages.
Either there is no power applied to the
enclosure or the enclosure is in a reset state.
1. Ensure that ac power is present at the
power controllers and that the array
controllers are on.
2. Ensure that there are at least four
operational power supplies.
3. Check the array controller optional
system maintenance terminal for error
messages.
LED is ON
LED is OFF