background image

© 2019 Ingersoll Rand All Rights Reserved

IMPORTANT — This document is customer property and is to remain with this unit. 

Please return to service information pack upon completion of work.

Flue Box Kit

Models:

BOX03706

BOX03707

BOX03708

BOX03709

KIT COMPONENTS:
Use these instructions when replacing the flue box:

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES.

SERVICE INSTALLER'S
GUIDE

WARNING

!

Disconnect power to the unit before removing the blower  

door. Failure to follow this warning could result in personal 

injury from moving parts.

18-CH99D1-1

Item 

No.

Drawing No.

Description

Qty

1

A340089P01

PRESSURE SWITCH TUBE

1

2

D345926P01

FLUE BOX

1

3

18-CH99CHD1-1

INSTALLER'S GUIDE

1

SHARP EDGE HAZARD!
Failure to follow this Caution could result in property damage or 
personal injury.  Be careful of sharp edges on equipment or any cuts 
made on sheet metal while installing or servicing.

CAUTION

!

WARNING

!

INSTALLATION OR REPAIRS MADE BY UNQUALIFIED 

PERSONS CAN RESULT IN HAZARDS TO YOU AND OTH-

ERS. INSTALLATION MUST CONFORM  WITH LOCAL CODES 

OR, IN THE ABSENCE OF LOCAL CODES, WITH CODES OF 

THE COUNTRY HAVING JURISDICTION. THE INFORMATION 

CONTAINED IN THESE  INSTRUCTIONS IS INTENDED FOR 

USE BY A QUALIFIED SERVICE TECHNICIAN FAMILIAR WITH 

SAFETY PROCEDURES AND EQUIPPED WITH THE PROPER 

TOOLS AND TEST INSTRUMENTS. FAILURE TO CARE-

FULLY READ AND FOLLOW ALL INSTRUCTIONS IN THESE 

INSTRUCTIONS CAN RESULT IN FURNACE OR BOILER 

MALFUNCTION, PROPERTY DAMAGE, PERSONAL INJURY 

AND/ OR DEATH.

Removing the flue box
1.  Turn the thermostat to the off position.
2.  Disconnect all electric power to the unit.
3.  Shut off the gas supply to unit.
4.  Remove the furnace door.
5.  Remove the inducer assembly.  Retain the screws 

for reinstallation.

6.  Disconnect the pressure switch tubing from the flue 

box.

7.  Remove the flue box.  Retain the screws for 

installation of the new flue box.

8.  Clean the heat exchanger surface.  
Note:  Make sure to remove all gasket material.

Furnace

Sealant

Flue Box screws

1