SET unit-number
2–77
HSZ40 Array Controller
CLI Reference Manual
SET
unit-number
Changes the characteristics of a unit.
Format
SET
unit-number
Parameters
unit-number
Specifies the logical unit number to modify. The unit-number is the name given the unit
when it was created using the
ADD UNIT
command.
Switches
Table 2–5 lists all switches for the
SET
unit-number command and shows which switches
can be used with each type of device and storageset. Descriptions of the switches follow
the table.
Table 2–5 Switches for the SET unit-number command
Switch
RAID-
set
Stripe-
set
Mirror-
set
NoTrans
Disk
Trans
Disk
CD–
ROM
Pass-
through
MAXIMUM_CACHED_
TRANSFER
9
9
9
9
9
9
PREFERRED_PATH
NOPREFERRED_PATH
(Default)
9
9
9
9
9
9
9
READ_CACHE (Default)
NOREAD_CACHE
9
9
9
9
9
9
RUN (Default)
NORUN
9
9
9
9
9
9
WRITE_PROTECT
NOWRITE_PROTECT
(Default)
9
9
9
9
9
WRITEBACK_CACHE
NOWRITEBACK_CACHE
(Default)
9
9
9
9
__________________________ Note _____________________________
The RUN/NORUN switch cannot be specified on partitioned units.
____________________________________________________________