SET THIS_CONTROLLER and SET OTHER_CONTROLLER
2–73
HSZ40 Array Controller
CLI Reference Manual
PREFERRED_ID=(n1[,nN] )
NOPREFERRED_ID
In an HSZ dual-redundant configuration,
PREFERRED
_
ID
defines which targets (and units)
are handled by the specified controller. You must first specify the total set of IDs with the
ID
switch. If you enter two or more
PREFERRED
_
ID
s, you must enclose the numbers in
parentheses and separate them with commas.
For example, if a dual-redundant pair of HSZ controllers is set to IDs 0, 1, and 2, you
could set one controller to respond to IDs 0 and 1; the other controller would automatically
respond to ID 2. The first controller would present unit numbers 0–7 and 100–107 and the
other controller would present unit numbers 200–207.
Except in an HSZ multiple bus failover environment, when you change the
PREFERRED
_
ID
s
on one controller, the other controller is automatically updated to support the remaining
IDs (if any).
Specifying
NOPREFERRED
_
ID
for one controller makes it a “hot standby.” The other
controller processes all I/O during normal operation. However, if that controller fails, the
controller with
NOPREFERRED
_
ID
would pick up the targets of the failed controller.
PROMPT="new prompt"
Specifies a 1- to 16-character prompt that is displayed when the controller's CLI prompts
for input. Only printable ASCII characters are valid and they must be enclosed in quotes.
When first installed, the CLI prompt is set to the first three letters of the controller's model
number (for example, HSZ>).
TERMINAL_PARITY=ODD
TERMINAL_PARITY=EVEN
NOTERMINAL_PARITY (Default)
Specifies the parity transmitted and expected.
TERMINAL_SPEED=baud_rate
Sets the terminal speed to 4800, 9600 (default), or 19200.
TIME=dd-mmm-yyyy:hh:mm:ss
The
TIME
switch sets the date and time. The time is set on both controllers in a dual-
redundant configuration.