![Digital Equipment HSZ40 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/digital-equipment/hsz40/hsz40_reference-manual_2498559039.webp)
CLEAR_ERRORS UNWRITEABLE_DATA
2–27
HSZ40 Array Controller
CLI Reference Manual
CLEAR_ERRORS UNWRITEABLE_DATA
Clears the unwriteable data error on a unit.
_________________________Caution____________________________
This command causes loss of user data.
____________________________________________________________
If a container fails in a way that user data in the write-back cache cannot be written to the
container, the controller reports an unwriteable data error. The
CLEAR
_
ERRORS
UNWRITEABLE
_
DATA
command removes the data from the cache and clears the unwriteable
data error.
Format
CLEAR_ERRORS
unit-number UNWRITEABLE_DATA
You must completely spell out “
UNWRITEABLE
_
DATA
.”
Parameters
unit-number
Specifies the unit number that will have the unwriteable data error cleared. The unit-
number is the name given the unit when it was created using the
ADD UNIT
command.
Examples
To clear the unwriteable data error on disk unit D103:
CLI> CLEAR_ERRORS D103 UNWRITEABLE_DATA
See also
CLEAR_ERRORS CLI
CLEAR_ERRORS INVALID_CACHE
CLEAR_ERRORS LOST_DATA
CLEAR_ERRORS UNKNOWN
RETRY_ERRORS UNWRITEABLE_DATA