LOCATE
2–43
HSZ40 Array Controller
CLI Reference Manual
Turns on the amber device fault LED on the device at the given SCSI location. SCSI-
location is specified in the form PTL where:
P designates the port (1–6 for 6-port controllers, or 1–3 for 3-port controllers).
T designates the target ID of the device, (0–6 with a single controller, or 0–5 with
dual-redundant controllers).
L designates the LUN of the device (must be 0 or 1).
When entering the PTL, you must put at least one space between the port, target, and LUN
numbers.
container-name
Turns on the amber fault LEDs on the devices that make up container-name. If a device
name is given, the device's LED is lit. If a storageset name is given, all device LEDs that
make up the storageset are lit. Use
LOCATE CANCEL
to turn off the LEDs.
unit-number
Turns on the amber fault LEDs on the devices that make up unit-number. Use
LOCATE
CANCEL
to turn off the LEDs.
Examples
To turn on the device fault LED on device DISK100 and then turn it off:
CLI> LOCATE DISK100
CLI> LOCATE CANCEL
To turn on the device fault LEDs on all devices that make up disk unit number 102:
CLI> LOCATE D102
To turn on the device fault LEDs on all configured disk devices:
CLI> LOCATE DISKS
To turn off the device fault LEDs on all devices:
CLI> LOCATE CANCEL