SET MULTIBUS_FAILOVER
2–67
HSZ40 Array Controller
CLI Reference Manual
Due to the amount of information that must be passed between the two controllers, this
command may take up to one minute to complete.
Example
To configure two controllers as dual-redundant in a multiple bus environment:
CLI> SET THIS_CONTROLLER ID=(0,1,2,3)
CLI> RESTART THIS_CONTROLLER
CLI> SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
The configuration on T
HIS
_
CONTROLLER
is automatically copied to the
O
THER
_
CONTROLLER
when you issue the
SET MULTIBUS
_
FAILOVER COPY
command. If you
want to prefer specific units to specific controllers, use the following command after
setting multiple bus failover command:
CLI> SET D100 PREFERRED=THIS_CONTROLLER
CLI> SET D101 PREFERRED=OTHER_CONTROLLER
See also
SET FAILOVER
SET NOFAILOVER