![Digital Equipment HSZ40 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/digital-equipment/hsz40/hsz40_reference-manual_2498559015.webp)
ADD DISK
2–3
HSZ40 Array Controller
CLI Reference Manual
ADD DISK
Adds a disk drive to the controller configuration and names the drive.
Format
ADD DISK
disk-name SCSI-location
Parameters
disk-name
Specifies a name for the disk drive. You use this name when adding the disk drive to a
storageset or with the
ADD UNIT
command to create a single-disk host-addressable unit.
The name must start with a letter (A–Z) and can then consist of up to eight more
characters made up of letters A-Z, numbers 0-9, periods (.), dashes (-), or underscores (_),
for a total of nine characters.
SCSI-location
The SCSI-location parameter assigns a PTL address to the disk drive. See page 1–5,
Specifying the Device PTL, for an explanation of the PTL numbering system.
Switches
TRANSPORTABLE
NOTRANSPORTABLE (Default)
Specify the
TRANSPORTABLE
switch for any disk drive that you want to move to and from
StorageWorks environments with the data intact.
__________________________ Note _____________________________
Use the
TRANSPORTABLE
switch only for disk drives that must be moved to
StorageWorks environments with data intact.
____________________________________________________________
A
TRANSPORTABLE
disk drive does not contain any special information space and can be
moved to a non-StorageWorks environment with its data intact. You cannot use a
TRANSPORTABLE
disk drive in any type of storageset, such as a stripeset or RAIDset.
Specify
NOTRANSPORTABLE
for all disk drives that will be used in RAIDsets, stripesets, and
mirrorsets. Also use the
NOTRANSPORTABLE
switch for all single-disk units that will be
used exclusively in a StorageWorks or HSC™ controller.
The controller makes a small portion of nontransportable
disk drives inaccessible to the
host and uses the space to store information (metadata) that improves data reliability, error
detection, and recovery. Because of this metadata, only StorageWorks controllers can
retrieve user data from nontransportable disk drives.