2–42
LOCATE
LOCATE
Identifies configured units, storagesets, and devices by flashing the amber device fault
LED on the front of the StorageWorks building block (SBB). The device fault LED will
flash once per second until turned off with the
LOCATE CANCEL
command. You also can use
the
LOCATE
command as a lamp test.
___________________________ Note ____________________________
The device fault LED flashes at a faster rate on any device that is in the
failedset. The different flashing rate should help you distinguish between located
devices and failed devices. The device fault LED on failed devices will continue
to flash after you issue the
LOCATE CANCEL
command.
____________________________________________________________
Format
LOCATE
Switches
ALL
Turns on the amber device fault LEDs of all configured devices. This switch also can be
used as a lamp test. Use
LOCATE CANCEL
to turn off the LEDs.
CANCEL
Turns off all amber device fault LEDs that were turned on with the
LOCATE
command.
DISKS
Turns on the amber device fault LEDs of all configured disk drives. Use
LOCATE CANCEL
to
turn off the LEDs.
UNITS
Turns on the amber device fault LEDs of all devices used by units. This command is
useful to determine which devices are not currently configured into logical units. Use
LOCATE CANCEL
to turn off device the LEDs.
PTL SCSI-location
___________________________ Note ____________________________
Although you can specify the PTL location or name of any device in the
subsystem, not all devices have a device fault LED, and so may not seem to
respond to the
LOCATE
command.
____________________________________________________________
Содержание HSZ40
Страница 6: ......
Страница 13: ...2 CLI Commands Descriptions of all CLI Commands Required Parameters Optional Switches Examples ...
Страница 24: ...2 12 ADD RAIDSET See also ADD UNIT DELETE SET RAIDSET SHOW RAIDSET INITIALIZE ...
Страница 101: ...HSZ40 Array Controller CLI Reference Manual Glossary ...
Страница 112: ......