2–64
SET mirrorset-name
Select
FAST
when the copy operation must take precedence over other controller
operations. The controller uses more resources and the copy takes less time, but overall
controller performance is reduced during the copy.
Examples
To change the replacement policy of mirrorset MIRR1 to
BEST
_
FIT
:
CLI> SET MIRR1 POLICY=BEST_FIT
The following example removes member DISK300 from mirrorset MIRR1 that was
created above. If the mirrorset has a replacement policy and an acceptable disk drive is in
the spareset, the controller automatically adds the spare disk drive to the mirrorset.
CLI> SET MIRR1 REMOVE=DISK300
To add disk drive DISK320 to the mirrorset MIRR1:
CLI> SET MIRR1 REPLACE=DISK320
A copy operation begins immediately on DISK320.