![Digital Equipment HSZ40 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/digital-equipment/hsz40/hsz40_reference-manual_2498559082.webp)
2–70
SET THIS_CONTROLLER and SET OTHER_CONTROLLER
SET THIS_CONTROLLER and SET OTHER_CONTROLLER
Changes parameters on the specified controller. T
HIS
_
CONTROLLER
is the controller that is
running the current CLI session. The O
THER
_
CONTROLLER
is the controller that is not
running the current CLI session.
Format
SET THIS_CONTROLLER
SET OTHER_CONTROLLER
Switches
Table 2–3 lists all switches for the
SET
T
HIS
_
CONTROLLER
and
SET
O
THER
_
CONTROLLER
commands and shows which switches can be used with each type of controller.
Descriptions of the switches follow the table.
Table 2–3 Switches for SET THIS and SET OTHER Command
Switch
HSZ Values
CACHE_FLUSH_TIMER
1 to 65535 sec, default
CACHE_POLICY
a, b
HOST_FUNCTION
A, B, C, D
ID
0-7 (x4)
INITIAL_CONFIGURATION
PREFERRED_ID
0-7 (x4)
PROMPT
1 to 16 characters
TERMINAL_PARITY
NOTERMINAL_PARITY
odd, even
TERMINAL_SPEED
4800, 9600, 19200
TIME
dd-mmm-yyy:
hh:mm:ss
TRANSFER_RATE_REQUESTED
asynchronous,
default,
10mHZ,
5mHZ
CACHE_FLUSH_TIMER=n
CACHE_FLUSH_TIMER=DEFAULT
Specifies how many seconds (1–65535) of idle time may elapse before the write-back
cache flushes its entire contents to disk. By default, this timer is set to 10 seconds. You
must restart the controller before changes to the
CACHE
_
FLUSH
_
TIMER
take effect.
Содержание HSZ40
Страница 6: ......
Страница 13: ...2 CLI Commands Descriptions of all CLI Commands Required Parameters Optional Switches Examples ...
Страница 24: ...2 12 ADD RAIDSET See also ADD UNIT DELETE SET RAIDSET SHOW RAIDSET INITIALIZE ...
Страница 101: ...HSZ40 Array Controller CLI Reference Manual Glossary ...
Страница 112: ......