2–58
SET FAILEDSET
SET FAILEDSET
Changes the automatic spare policy for the failedset.
Format
SET FAILEDSET
Switches
AUTOSPARE
NOAUTOSPARE (Default)
The
AUTOSPARE
switch allows you to enable automatic moving of replaced disk drives
from the failedset to the spareset. When a disk drive in the failedset is replaced with a
factory-fresh drive and this feature is enabled, the controller automatically removes that
disk drive from the failedset and adds it to the spareset, where it is available as a hot spare
for RAIDsets and mirrorsets.
Specify
AUTOSPARE
to enable the feature. Specify
NOAUTOSPARE
to disable the feature.
Examples
To enable the automatic spare feature:
CLI> SET FAILEDSET AUTOSPARE
See also
SHOW FAILEDSET