Connecting to the Network
DLE49-MA User’s Guide
3-5
3.5
CONNECTING TO THE NETWORK
This section provides the procedures for connecting unshielded twisted
pair (UTP) segments to the modules.
To make connections to an optional HSIM installed in the HSIM slot of a
DLE49-MA, refer to the instructions shipped with that device.
When facing the front panel of a DLE49-MA, the top-left RJ21 is the
connector for 10BASE-T ports 1 through 12; bottom left, ports 13
through 24; top-right, ports 25 through 36; and bottom-right, ports 37
through 48. All 48 ports have internal crossovers.
To connect an RJ21, proceed as follows:
1.
Ensure that the device connected to the other end of the segment is
powered ON.
2.
If using an RJ21 straight connector, plug it into the appropriate RJ21
port as shown in
Figure 3-2
or, if using the RJ21 right-angled adapter
supplied with the device, insert it as shown in
Figure 3-3
. The RJ21
right-angled adapter enables the cables to be dressed closely along the
front of the device.
If the device is being installed in a network using
SmartTrunking, there are rules concerning the cable
connections and port configurations that must be followed for
SmartTrunking to operate properly. Before connecting the
cables, refer to the
SmartTrunk User’s Guide for the
configuration information.
Содержание DLE49-MA
Страница 1: ...DIGITAL MultiSwitch 700ET DLE49 MA Interface Module User s Guide...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 18: ......
Страница 44: ......
Страница 46: ......
Страница 188: ......
Страница 200: ......
Страница 215: ......
Страница 216: ...9032831 Printed in U S A...