Port Redirect Configuration Screen
DLE49-MA User’s Guide
6-45
Figure 6-17
Port Redirect Configuration Screen
The following definitions briefly explain each field of the Port Redirect
Configuration screen:
Source Port (Read-Only)
Shows which ports are currently set as source ports.
Destination Port (Read-Only)
Shows which ports are currently set as destination ports. Only one
destination port may be assigned to a source port.
Frame Format (Read-Only)
Displays the current frame format setting: NORMAL, TAGGED or
UNTAGGED The default is NORMAL.
•
NORMAL – Frames are redirected in the format that they were
received or transmitted on the source port.
•
TAGGED – Frames are transmitted on the destination port with a
VLAN tag inserted according to the frame classification.
Port Redirect Configuration
2693-22
Source Port
1
3
6
Destination Port
2
4
9
Redirect Errors
ON
ON
OFF
============
============
============
Frame Format
NORMAL
TAGGED
UNTAGGED
============
Redirect Errors [OFF]
MS700 LOCAL MANAGEMENT
Event Message Line
SAVE
PREVIOUS
RETURN
RETURN
NEXT
Source Port [1]
Destination Port [1]
Status [ADD]
EXIT
Frame Format [UNTAGGED]
Firmware Revision: XX.XX.XX
Module Type: DLE49-MA
BOOTPROM Revision: XX.XX.XX