Chapter 5: Local Management: Overview, Setup, and Chassis Management
5-24
DLE49-MA User’s Guide
5.8.6
Setting the Screen Lockout Time
The screen lockout time can be set from 1 to 30 minutes with a default of
15 minutes. To set a new lockout time, perform the following steps:
1.
Use the arrow keys to highlight the Screen Lockout Time field.
2.
Enter a number from 1 to 30.
3.
Press ENTER to set the lockout time in the input field.
4.
Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
If the time entered is within the 1 to 30 minutes range, the Event Message
Line at the top of the screen displays “SAVED OK”. If the entry is not
valid, Local Management does not alter the current setting, but it does
refresh the Screen Lockout Time field with the previous value.
5.9
SNMP COMMUNITY NAMES SCREEN
The SNMP Community Names menu item allows the user to set Local
Management community names. Community names act as passwords to
Local/Remote Management and provide security access to the
DLM6C-AA. Access to the DLM6C-AA is controlled by enacting any of
three different levels of security authorization (read-only, read-write, and
super-user).
To access the SNMP Community Names screen from the Chassis Menu
screen, use the arrow keys to highlight the SNMP COMMUNITY
NAMES menu item and press ENTER. The SNMP Community Names
screen,
Figure 5-9
, displays.
Super-User access gives the user full management privileges,
allows existing passwords to be changed, and all modifiable
MIB objects for the Cabletron Container MIB and Internet
MIB-II to be edited.
Содержание DLE49-MA
Страница 1: ...DIGITAL MultiSwitch 700ET DLE49 MA Interface Module User s Guide...
Страница 2: ......
Страница 8: ......
Страница 14: ......
Страница 18: ......
Страница 44: ......
Страница 46: ......
Страница 188: ......
Страница 200: ......
Страница 215: ......
Страница 216: ...9032831 Printed in U S A...