12
Chapter 2 Basic Functions and Operational Flow
2.3
User Levels and Access Rights
WINCAPS III's two user access levels, operator and programmer, ensure data security by limiting access to ad-
vanced functionality and sensitive data.
The user specifies which on the log-in screen when WINCAPS III first starts.
For further details on logging in, refer to 3.1 "Loading WINCAPS III" (P. 13).
Operator level
Level enabling PAC program creation / editing and other basic operations.
It blocks changes to WINCAPS III settings.
It does not require a password.
Programmer level
Level enabling changes in project settings and other higher operations.
It allows changes to WINCAPS III settings.
It requires a password.
For further details on setting this password, refer to 3.1.2 "Programmer password" (P. 17).
Differences in functions due to user levels are as follows.
*Only communications settings can be changed
Note
Changing user levels while WINCAPS III is running requires returning to the dialog box for logging in.
Function
Operator
Programmer
Creating a new project
{
{
Writing / editing programs
{
{
Data transfers
{
{
Online (monitoring/debugging functions)
{
{
Addition of controller function extension
{
{
Altering project properties
U
*
{
Altering parameters
×
{
Reading / writing arm parameters
×
{