Chapter 8 Logging
121
8.1
Log record timing
Logs are recorded at four different times as follows.
• Regular recording
Error logs and operational logs are regularly recorded. 1,000 logs can be recorded for each, with the latest
1,000 being retained.
• Manual recording by WINCAPS III or the teach pendant.
Recording can be started and stopped manually using WINCAPS III or the teach pendant.
• Recording by program commands
Settings are available to start / stop log records or clear them in programs. This is used when you wish to
record a particular operation in a program. The three commands used are STARTLOG, STOPLOG and
CLEARLOG.
It is also possible to determine the range of logging by specifying program lines in WINCAPS III.
• Error trigger log
A record log is saved in flash memory when a specified error occurs. Error logs, operational logs, control logs
and trace logs (multi) are available. This is used when searching for the causes of errors.
Errors specifiable by the error trigger are of two types: those specified by error level and those of a particular
error code.