Geo MACRO Drive User and Reference Manual
Geo Macro Drive MI-Variable Reference
147
MS{node},MI912 Secondary Encoder Index Capture Control
Range:
0 - 15
Units:
none
Default:
0
This parameter determines for the index flag which polarity, triggers a position capture of the counter for
the secondary encoder mapped to the specified node. If a flag input (home or index) is used, MI915 for
the node determines which flag. Proper setup of this variable is essential for a successful home search,
which depends on the position-capture function. The following settings may be used:
0:
Capture on Index (CHCn) rising edge
1:
Capture on Index (CHCn) falling edge
The trigger is armed when the position capture register is read. After this, as soon as the Geo MACRO
Station sees that the specified input lines are in the specified states, the trigger will occur -- it is edge-
trigger, not level-triggered.
MS{node},MI913 Secondary Encoder Home Flag Capture Control
Range:
0 - 15
Units:
none
Default:
0
This parameter determines for the Home flag which polarity, triggers a position capture of the counter for
the secondary encoder mapped to the specified node. If a flag input (index or Home flag) is used, MI915
for the node determines which flag. Proper setup of this variable is essential for a successful home
search, which depends on the position-capture function. The following settings may be used:
0:
Capture on HOME flag rising edge
1:
Capture on HOME flag falling edge
The trigger is armed when the position capture register is read. After this, as soon as the Geo MACRO
Station sees that the specified input lines are in the specified states, the trigger will occur -- it is edge-
trigger, not level-triggered.
MS{node},MI914 Secondary Encoder Filter Control
Range:
0 - 256
Units:
40Mhz Clock Cycles
Default:
0
MI914 controls the rate at which the input signals of the secondary encoder for the specified node are
sampled. The inputs are sampled every (MI914+1) clock cycles, where each clock cycle is
25nanoseconds. Higher values of MI914 can filter out longer noise spikes, but permit lower count rates,
as only one quadrature edge per sample period can be accepted
Содержание Geo MACRO
Страница 2: ......
Страница 6: ......
Страница 18: ...Geo MACRO Drive User Manual 6 Introduction...
Страница 26: ...Geo MACRO Drive User Manual 14 Specifications...
Страница 28: ...Geo MACRO Drive User Manual 16 Receiving and Unpacking...
Страница 78: ...Geo MACRO Drive User Manual 66 Software Setup...
Страница 88: ...Geo MACRO Drive User Manual 76 Setting Up Secondary Encoders...
Страница 90: ...Geo MACRO Drive User Manual 78 Setting Up Turbo PMAC Conversion Table...
Страница 110: ...Geo MACRO Drive User Manual 98 Setting Up Turbo Motor Operation...
Страница 130: ...Geo MACRO Drive User Manual 118 Troubleshooting...
Страница 175: ...Geo MACRO Drive User and Reference Manual Absolute Power On Online Commands 163...
Страница 176: ...Geo MACRO Drive User Manual 164 Useful Notes...
Страница 177: ...Geo MACRO Drive User and Reference Manual Appendix A 165...
Страница 182: ...Geo MACRO Drive User Manual 170 Appendix A Cable Drawings...
Страница 183: ...Geo MACRO Drive User and Reference Manual Appendix A 171...
Страница 184: ...Geo MACRO Drive User Manual 172 Appendix A...
Страница 185: ...Geo MACRO Drive User and Reference Manual Appendix A 173...
Страница 186: ...Geo MACRO Drive User Manual 174 Appendix A...
Страница 187: ...Geo MACRO Drive User and Reference Manual Appendix A 175...
Страница 191: ...Geo MACRO Drive User and Reference Manual Appendix A 179...
Страница 197: ...Geo MACRO Drive User and Reference Manual Appendix C 185...