Geo MACRO Drive User and Reference Manual
Specifications
13
Environmental Specifications
Description Unit
Specifications
Operating Temperature
°C
+0 to 45°C. Above 45°C, derate the continuous peak output current by
2.5% per °C above 45°C. Maximum Ambient is 55°C
Rated Storage Temperature
°C
-25 to +70
Humidity
%
10% to 90% non-condensing
Shock
Call
Factory
Vibration
Call
Factory
Operating Altitude
Feet
(Meters)
To 3300 feet (1000meters). Derate the continuous and peak output
current by 1.1% for each 330 feet (100meters) above the 3300feet
Air Flow Clearances
in (mm) 3" (76.2mm) above and below unit for air flow
Recommended Fusing and Wire Gauge
Model
Recommended Fuse (FRN/LPN) Recommended Wire Gauge*
GxL012xx 15
14
AWG
GxL032xx 20
12
AWG
GxL051xx 20
12
AWG
GxL052xx 20
12
AWG
GxL101xx 20
12
AWG
GxL102xx 20
12
AWG
GxL151xx 25
10
AWG
GxL152xx 25
10
AWG
GxL201xx 25
10
AWG
GxL301xx 30
8
AWG
GxH012xx 15
14
AWG
GxH032xx 20
12
AWG
GxH051xx 20
12
AWG
GxH052xx 20
12
AWG
GxH101xx 20
12
AWG
GxH102xx 20
12
AWG
GxH151xx 25
10
AWG
GxH152xx 25
10
AWG
GxH201xx 25
10
AWG
GxH301xx 30
8
AWG
* See local and national code requirements
Wire Sizes
Geo Drive electronics create a DC bus by rectifying the incoming AC electricity. The current flow into
the drive is not sinusoidal but rather a series of narrow, high-peak pulses. Keep the incoming impedance
small so that these current pulses are not hindered. Conductor size, transformer size, and fuse size
recommendations may seem larger than normally expected. All ground conductors should be 8AWG
minimum using wires constructed of many strands of small gauge wire. This provides the lowest
impedance to high-frequency noises.
Содержание Geo MACRO
Страница 2: ......
Страница 6: ......
Страница 18: ...Geo MACRO Drive User Manual 6 Introduction...
Страница 26: ...Geo MACRO Drive User Manual 14 Specifications...
Страница 28: ...Geo MACRO Drive User Manual 16 Receiving and Unpacking...
Страница 78: ...Geo MACRO Drive User Manual 66 Software Setup...
Страница 88: ...Geo MACRO Drive User Manual 76 Setting Up Secondary Encoders...
Страница 90: ...Geo MACRO Drive User Manual 78 Setting Up Turbo PMAC Conversion Table...
Страница 110: ...Geo MACRO Drive User Manual 98 Setting Up Turbo Motor Operation...
Страница 130: ...Geo MACRO Drive User Manual 118 Troubleshooting...
Страница 175: ...Geo MACRO Drive User and Reference Manual Absolute Power On Online Commands 163...
Страница 176: ...Geo MACRO Drive User Manual 164 Useful Notes...
Страница 177: ...Geo MACRO Drive User and Reference Manual Appendix A 165...
Страница 182: ...Geo MACRO Drive User Manual 170 Appendix A Cable Drawings...
Страница 183: ...Geo MACRO Drive User and Reference Manual Appendix A 171...
Страница 184: ...Geo MACRO Drive User Manual 172 Appendix A...
Страница 185: ...Geo MACRO Drive User and Reference Manual Appendix A 173...
Страница 186: ...Geo MACRO Drive User Manual 174 Appendix A...
Страница 187: ...Geo MACRO Drive User and Reference Manual Appendix A 175...
Страница 191: ...Geo MACRO Drive User and Reference Manual Appendix A 179...
Страница 197: ...Geo MACRO Drive User and Reference Manual Appendix C 185...