If one of the new stacks receives only the standby unit, it becomes the master unit of the new stack, and Dell Networking OS elects a
new standby unit.
•
If one of the new stacks receives neither the master nor the standby management unit, the stack is reset so that a new election can
take place.
Stacking Configuration Tasks
Following are the stacking configuration tasks:
•
Assigning Unit Numbers to Units in a Stack
•
Creating a Virtual Stack Unit in a Stack
•
Displaying Information About a Stack
•
Influencing Management Unit Selection on a Stack
•
Managing Redundancy on a Stack
•
•
Assigning Unit Numbers to Units in an Stack
Each unit in the stack has a stack number that is either assigned by you or Dell Networking OS.
Units are numbered from 1 to 6. Stack numbers are stored in NVRAM and are preserved upon reload.
•
Assign a stack-number to a unit.
EXEC Privilege mode
stack-unit
old-unit-number
renumber
new-unit-number
Renumbering the stack manager triggers the whole stack to reload, as shown in the message below. When the stack comes back online,
the master unit remains the management unit.
Dell#stack-unit 2 renumber 1
Renumbering master unit will reload the stack.
WARNING: Interface configuration for current unit will be lost!
Proceed to renumber [confirm yes/no]: yes
Creating a Virtual Stack Unit on a Stack
Use virtual stack units to configure ports on the stack before adding a new unit.
•
Create a virtual stack unit.
CONFIGURATION mode
stack-unit
stack-unit-number
provision
S4048–ON
Displaying Information about a Stack
To display information about the stack, use the following command.
•
Display for stack-identity, status, and hardware information on every unit in a stack.
EXEC Privilege mode
show system
•
Display most of the information in show system, but in a more convenient tabular form.
910
Stacking
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Страница 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...