EXEC Privilege mode
show system brief
3
Start diagnostics on the unit.
diag stack-unit
stack-unit-number
When the tests are complete, the system displays the following message and automatically reboots the unit.
Dell#00:09:42 : Diagnostic test results are stored on file: flash:/TestReport-SU-0.txt
Diags completed... Rebooting the system now!!!
Mar 12 10:40:35: %S4810:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 0
Dell#00:09:42 : Diagnostic test results are stored on file: flash:/TestReport-SU-0.txt
Diags completed... Rebooting the system now!!!
Mar 12 10:40:35: %S6000:0 %DIAGAGT-6-DA_DIAG_DONE: Diags finished on stack unit 1
Diagnostic results are printed to a file in the flash using the filename format
TestReport-SU-<stack-unit-id>.txt
.
Log messages differ somewhat when diagnostics are done on a standalone unit and on a stack member.
4
View the results of the diagnostic tests.
EXEC Privilege mode
show file flash://TestReport-SU-
stack-unit-id
.txt
Examples of Running Offline Diagnostics
The following example shows the
offline stack-unit
id
command.
The following example shows the
show system brief
command.
Dell#show system brief
Stack MAC : 00:01:e8:8b:5d:8c
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------------
0 Management online S4810 S4810 9-4(0-89) 64
1 Member not present
2 Member not present
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
-- Power Supplies --
Unit Bay Status Type FanSpeed(rpm)
---------------------------------------------------------------------------
0 0 down UNKNOWN 0
0 1 up AC 14000
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
0 0 up up 13466 up 13466
0 1 up up 13653 up 13466
Speed in RPM
Debugging and Diagnostics
1109
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Страница 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...