Example of Viewing sFlow Configuration (Line Card)
Dell#show sflow Stack-unit 1
Stack-unit 1
Samples rcvd from h/w :0
Total UDP packets exported :0
UDP packets exported via RPM :0
UDP packets dropped :36
Configuring Specify Collectors
The
sflow collector
command allows identification of sFlow collectors to which sFlow datagrams are forwarded.
You can specify up to two sFlow collectors. If you specify two collectors, the samples are sent to both.
•
Identify sFlow collectors to which sFlow datagrams are forwarded.
CONFIGURATION mode
sflow collector
ip-address
agent-addr
ip-address
[
number
[max-datagram-size
number
] ] | [max-
datagram-size
number
]
The default UDP port is
6343
.
The default max-datagram-size is
1400
.
Changing the Polling Intervals
The
sflow polling-interval
command configures the polling interval for an interface in the maximum number of seconds between
successive samples of counters sent to the collector.
This command changes the global default counter polling (20 seconds) interval. You can configure an interface to use a different polling
interval.
To configure the polling intervals globally (in CONFIGURATION mode) or by interface (in INTERFACE mode), use the following command.
•
Change the global default counter polling interval.
CONFIGURATION mode or INTERFACE mode
sflow polling-interval
interval value
•
interval value
: in seconds.
The range is from 15 to 86400 seconds.
The default is
20 seconds
.
Back-Off Mechanism
If the sampling rate for an interface is set to a very low value, the CPU can get overloaded with flow samples under high-traffic conditions.
In such a scenario, a binary back-off mechanism gets triggered, which doubles the sampling-rate (halves the number of samples per
second) for all interfaces. The backoff mechanism continues to double the sampling-rate until the CPU condition is cleared. This is as per
sFlow version 5 draft. After the back-off changes the sample-rate, you must manually change the sampling rate to the desired value.
As a result of back-off, the actual sampling-rate of an interface may differ from its configured sampling rate. You can view the actual
sampling-rate of the interface and the configured sample-rate by using the
show sflow
command.
sFlow
857
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Страница 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...