Verify that the port has been authorized and placed in the desired VLAN (refer to the illustration in
).
Guest and Authentication-Fail VLANs
Typically, the authenticator (the Dell system) denies the supplicant access to the network until the supplicant is authenticated. If the
supplicant is authenticated, the authenticator enables the port and places it in either the VLAN for which the port is configured or the
VLAN that the authentication server indicates in the authentication data.
NOTE:
Ports cannot be dynamically assigned to the default VLAN.
If the supplicant fails authentication, the authenticator typically does not enable the port. In some cases this behavior is not appropriate.
External users of an enterprise network, for example, might not be able to be authenticated, but still need access to the network. Also,
some dumb-terminals, such as network printers, do not have 802.1X capability and therefore cannot authenticate themselves. To be able to
connect such devices, they must be allowed access the network without compromising network security.
The Guest VLAN 802.1X extension addresses this limitation with regard to non-802.1X capable devices and the Authentication-fail VLAN
802.1X extension addresses this limitation with regard to external users.
•
If the supplicant fails authentication a specified number of times, the authenticator places the port in the Authentication-fail VLAN.
•
If a port is already forwarding on the Guest VLAN when 802.1X is enabled, the port is moved out of the Guest VLAN and the
authentication process begins.
Configuring a Guest VLAN
If the supplicant does not respond within a determined amount of time ([reauth-max + 1] * tx-period, the system assumes that the host
does not have 802.1X capability and the port is placed in the Guest VLAN.
NOTE:
For more information about configuring timeouts, refer to
.
Configure a port to be placed in the Guest VLAN after failing to respond within the timeout period using the
dot1x guest-vlan
command from INTERFACE mode. View your configuration using the
show config
command from INTERFACE mode or using the
show
dot1x interface
command from EXEC Privilege mode.
Example of Viewing Guest VLAN Configuration
Dell(conf-if-Te-2/1)#dot1x guest-vlan 200
Dell(conf-if-Te 2/1))#show config
!
interface TenGigabitEthernet 2/1
switchport
dot1x guest-vlan 200
no shutdown
Dell(conf-if-Te 2/1))#
Configuring an Authentication-Fail VLAN
If the supplicant fails authentication, the authenticator re-attempts to authenticate after a specified amount of time.
NOTE:
For more information about authenticator re-attempts, refer to
Configuring a Quiet Period after a Failed
.
You can configure the maximum number of times the authenticator re-attempts authentication after a failure (
3
by default), after which the
port is placed in the Authentication-fail VLAN.
802.1X
101
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Страница 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...