Configuring Contact and Location Information using
SNMP
You may configure system contact and location information from the Dell Networking system or from the management station using
SNMP.
To configure system contact and location information from the Dell Networking system and from the management station using SNMP, use
the following commands.
•
(From a Dell Networking system) Identify the system manager along with this person’s contact information (for example, an email
address or phone number).
CONFIGURATION mode
snmp-server contact
text
You may use up to 55 characters.
The default is
None
.
•
(From a Dell Networking system) Identify the physical location of the system (for example, San Jose, 350 Holger Way, 1st floor lab, rack
A1-1).
CONFIGURATION mode
snmp-server location
text
You may use up to 55 characters.
The default is
None
.
•
(From a management station) Identify the system manager along with this person’s contact information (for example, an email address
or phone number).
CONFIGURATION mode
snmpset -v
version
-c
community agent-ip sysContact.0 s “contact-info”
You may use up to 55 characters.
The default is
None
.
•
(From a management station) Identify the physical location of the system (for example, San Jose, 350 Holger Way, 1st floor lab, rack
A1-1).
CONFIGURATION mode
snmpset -v
version
-c
community agent-ip sysLocation.0 s “location-info”
You may use up to 55 characters.
The default is
None
.
Subscribing to Managed Object Value Updates using
SNMP
By default, the Dell Networking system displays some unsolicited SNMP messages (traps) upon certain events and conditions.
You can also configure the system to send the traps to a management station. Traps cannot be saved on the system.
Dell Networking OS supports the following three sets of traps:
•
RFC 1157-defined traps
— coldStart, warmStart, linkDown, linkUp, authenticationFailure, and egpNeighbborLoss.
866
Simple Network Management Protocol (SNMP)
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Страница 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...