diagS4810ChkPsuPresence[625]: ERROR: Psu : 0 is not present
Test 2.000 - Fan Psu Status test .................................... NOT PRESENT
Test 2.001 - Fan Psu Status test .................................... PASS
Test 2 - Fan Psu Status Test ....................................... FAIL
Test 3.000 - Fan board presence Test ................................ PASS
Test 3.001 - Fan board presence Test ................................ PASS
Test 3 - Fan Board Presence Test ................................... PASS
Test 4.000 - Board Fan Status Test .................................. PASS
Test 4.001 - Board Fan Status Test .................................. PASS
Test 4.002 - Board Fan Status Test .................................. PASS
Test 4.003 - Board Fan Status Test .................................. PASS
Test 4 - Board Fan Status Test ..................................... PASS
Test 5 - Fan Tray Air Flow Status Test ............................. PASS
Test 6.000 - TMP75A-CPU ............................................. PASS
Test 6.001 - TMP75B-MAC ............................................. PASS
Test 6.002 - TMP75C-LEFT-PHY ........................................ PASS
Test 6.003 - TMP75D-RIGHT-PHY ....................................... PASS
Test 6 - Temp Sensor Access Test .................................... PASS
Test 7 - RTC Presence Test .......................................... PASS
Test 8 - SDRAM Presence Test ........................................ PASS
Test 10 - Board revision Test ....................................... PASS
Test 11 - MGMT PHY Presence Test .................................... PASS
Test 12 - Board voltage Test ........................................ PASS
Trace Logs
In addition to the syslog buffer, Dell Networking OS buffers trace messages which are continuously written by various Dell Networking OS
software tasks to report hardware and software events and status information.
Each trace message provides the date, time, and name of the Dell Networking OS process. All messages are stored in a ring buffer. You can
save the messages to a file either manually or automatically after failover.
Auto Save on Crash or Rollover
Exception information for MASTER or standby units is stored in the
flash:/TRACE_LOG_DIR
directory. This directory contains files that
save trace information when there has been a task crash or timeout.
•
On a MASTER unit, you can reach the
TRACE_LOG_DIR
files by FTP or by using the
show file
command from the
flash://
TRACE_LOG_DIR
directory.
•
On a Standby unit, you can reach the
TRACE_LOG_DIR
files only by using the
show file
command from the
flash://
TRACE_LOG_DIR
directory.
NOTE:
Non-management member units do not support this functionality.
Last Restart Reason
If the system restarts for some reason (automatically or manually), the
show system
command output includes the reason for the
restart.
The following table shows the reasons displayed in the output and their corresponding causes.
Table 113. Line Card Restart Causes and Reasons
Causes
Displayed Reasons
Remote power cycle of the chassis
push button reset
reload
soft reset
reboot after a crash
soft reset
Debugging and Diagnostics
1111
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...