-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 up UNKNOWN up 10736
1 2 absent absent 0
2 1 up UNKNOWN up 10768
2 2 down UNKNOWN down 0
3 1 up UNKNOWN up 10672
3 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
1 1 up up 10134 up 10031
1 2 up up 10031 up 9929
1 3 up up 10031 up 10031
2 1 up up 10031 up 10031
2 2 up up 10031 up 10031
2 3 up up 10031 up 10134
3 1 up up 10031 up 10134
3 2 up up 10031 up 10031
3 3 up up 10031 up 10031
Speed in RPM
Dell#
The following example shows the
show system stack-ports
command.
Dell#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin Link Trunk
(Gb/s) Status Status Group
------------------------------------------------------------------
1/56 3/56 40 up up
1/60 3/60 40 up up
3/48 40 up down
3/52 40 up down
3/56 0/56 40 up up
3/60 0/60 40 up up
Influencing Management Unit Selection on a Stack
Stack priority is the system variable that Dell Networking OS uses to determine which units in the stack are the master and standby
management units. If multiple units tie for highest priority, the unit with the highest MAC address prevails.
If management was determined by priority only, a change in management occurs when:
•
the management unit is powered down or a failover occurs.
•
you disconnect the management unit from the stack.
When the management unit fails, the unit disappears from the stack topology. At that time, the standby unit detects the communication
loss and switches from the standby unit role to the management unit role in the stack. From the remaining units in the stack, the system
selects a new standby unit based on the unit priority using the same algorithm used when the stack was initially created. When the failed
unit recovers, it takes the next available role, usually that of a stack member.
•
Influence the selection of the stack management units.
CONFIGURATION mode
stack-unit
unit-number
priority
priority-value
The unit with the numerically highest priority is elected the master management unit, and the unit with the second highest priority is
the standby unit.
The range is from 1 to 14.
Stacking
913
Содержание S4048T-ON
Страница 1: ...Dell Configuration Guide for the S4048 ON System 9 11 2 1 ...
Страница 148: ...Figure 10 BFD Three Way Handshake State Changes 148 Bidirectional Forwarding Detection BFD ...
Страница 251: ...Dell Control Plane Policing CoPP 251 ...
Страница 363: ... RPM Synchronization GARP VLAN Registration Protocol GVRP 363 ...
Страница 511: ...Figure 64 Inspecting the LAG Configuration Link Aggregation Control Protocol LACP 511 ...
Страница 512: ...Figure 65 Inspecting Configuration of LAG 10 on ALPHA 512 Link Aggregation Control Protocol LACP ...
Страница 515: ...Figure 67 Inspecting a LAG Port on BRAVO Using the show interface Command Link Aggregation Control Protocol LACP 515 ...
Страница 516: ...Figure 68 Inspecting LAG 10 Using the show interfaces port channel Command 516 Link Aggregation Control Protocol LACP ...
Страница 558: ...Figure 84 Configuring Interfaces for MSDP 558 Multicast Source Discovery Protocol MSDP ...
Страница 559: ...Figure 85 Configuring OSPF and BGP for MSDP Multicast Source Discovery Protocol MSDP 559 ...
Страница 560: ...Figure 86 Configuring PIM in Multiple Routing Domains 560 Multicast Source Discovery Protocol MSDP ...
Страница 564: ...Figure 88 MSDP Default Peer Scenario 2 564 Multicast Source Discovery Protocol MSDP ...
Страница 565: ...Figure 89 MSDP Default Peer Scenario 3 Multicast Source Discovery Protocol MSDP 565 ...
Страница 729: ...protocol spanning tree pvst no disable vlan 300 bridge priority 4096 Per VLAN Spanning Tree Plus PVST 729 ...
Страница 841: ...Figure 115 Single and Double Tag TPID Match Service Provider Bridging 841 ...
Страница 842: ...Figure 116 Single and Double Tag First byte TPID Match 842 Service Provider Bridging ...