Script Commands
157
Disable Storage Array Feature
This command disables a storage array feature. Run the
show
storageArray
command to display a list of the feature identifiers for all
enabled features in the storage array.
Syntax
disable storageArray [featurePack |
feature=(storagePartition2 | storagePartition4 |
storagePartition8 | storagePartition16 |
storagePartition32 | storagePartition64 |
storagePartition96 | storagePartition128
|storagePartition256 | storagePartitionMax |
snapshot2 | snapshot4 | snapshot8 | snapshot16 |
remoteMirror8 | remoteMirror16 | remoteMirror32 |
remoteMirror64 | remoteMirror128 | virtualDiskCopy
| goldKey | mixedPhysicalDiskTypes |
highPerformanceTier | SSDSupport]
Parameters
None.
testID
Identifier for the diagnostic test to run.
The identifier and corresponding tests
are:
1
— Reads the test
2
— Write test
3
— Data loop-back test
NOTE:
When you run a data loop-back test,
you can optionally specify a file that
contains a data pattern. If you do not
specify a file, the RAID controller module
firmware provides a default pattern.
patternFile
Name of a file that contains a data
pattern to use as test data. You must put
quotation marks (" ") around the data
pattern file name.
Parameter
Description
book.book Page 157 Friday, March 4, 2011 10:45 AM